Skip to main content
Built by KoderTroop · Healthcare IoT

Contactless Patient Monitoring: The Healthcare IoT Smart Bed

Vital signs, sleep, breathing and bed exits monitored continuously from sensors in or under the mattress. Patients wear nothing, and nothing is attached to the body.

Contactless Patient Monitoring screen
Monitoring Between Rounds, Without Wearables

Monitoring Between Rounds, Without Wearables

Manual vital-sign rounds capture a patient at intervals, and anything attached to the body has to be fitted and tolerated. This system instead turns a standard hospital or home-care bed into a monitoring point. Sensors in or under the mattress capture the mechanical signals of the heartbeat and breathing, along with movement and position. Embedded signal processing and AI analytics convert them into vital signs, sleep and respiratory insight, and alerts for nurses and caregivers, as decision support for the care team.

How Contactless Patient Monitoring Works

The screens your team works in each day, and what each one is for.

Ward 3 · Bed 12 · PT-20931
Under-mattress sensor MS-4471 · ballistocardiography · updated 23:48:06
Live1 h8 h24 hSN
Heart rate
68 bpm
Tonight 61–79
Respiratory rate
15 rpm
Tonight 12–18
Heart rate variability
42 ms
RMSSD · 5 min window
Bed occupancy
In bed
Since 20:02 · 3 h 46 m
Signal quality
Good
Low motion artefact
Heart · ballistocardiogramTracking
Live signal · last 5 sbeat interval 0.88 s
Heart rate · last 60 minbpm
22:4823:0323:1823:3323:48
Breathing · respiratory effortRegular
Live signal · last 30 sbreath interval 4.0 s
Respiratory rate · last 60 minrpm
22:4823:0323:1823:3323:48
Sensor
SensingBCG + pressure array
PlacementUnder mattress
Sensor IDMS-4471
Firmware2.8.3
Last data23:48:06
Signal strengthGood
Alert limitsThis patient
Heart rate50–110 bpm
Respiratory rate10–24 rpm
HRVBelow 25 ms
Bed exit21:00–07:00
Limits set by the care team.
Night summary · Ward 3 · Bed 12
PT-20931 · in bed 22:00 – 06:30 · estimated from under-mattress sensing
Last night7 nightsReportSN
Time asleep
6 h 56 m
In bed 8 h 30 m
Sleep onset
23:14
Final wake 06:20
Awakenings
3
Longest 10 min
Breathing events
3
For clinical review
Snoring
38 min
Mostly supine
Respiratory rate
14 rpm
Asleep · range 13–19
Estimated sleep stages22:00 – 06:30
AwakeREMLightDeep22:0000:0002:0004:0006:00
Deep1 h 34 m
Light3 h 52 m
REM1 h 30 m
Awake1 h 34 m
Respiratory rate overnightrpm · 15 min average
E1E2E3
22:0000:0002:0004:0006:00
Breathing events3 to review
E1
Breathing pause · 14 s
01:20 · light sleep · supine
Review
E2
Breathing pause · 11 s
03:18 · light sleep · supine
Review
E3
Irregular breathing · 3 min
05:16 · light sleep · left side
Review
S
Snoring · 38 min in total
Mostly 00:58–02:40 · supine
Logged
Screening for clinical review, not a diagnosis.
Ward 3 · night shift
Bed occupancy, position and movement · live at 02:14
All bedsAlertsFall riskSN
Beds 01–16In bedNeeds attentionBed exit or fall riskEmptyMovement · 2 h
Bed 01PT-20914
In bed
SupineIn bed 6 h 40 m
Bed 02PT-20918
In bed
Left sideTurned 01:30
Bed 03—
Empty
No patientDischarged 18:20
Bed 04PT-20922
Restless
Right sideRestless 36 min
Bed 05PT-20925
In bed
SupineIn bed 5 h 05 m
Bed 06PT-20927
Reposition due
SupineSame position 2 h 10 m
Bed 07PT-20929
Out of bed
Bed emptyLeft bed 02:13
Bed 08PT-20930
In bed
Right sideIn bed 4 h 52 m
Bed 09PT-20933
In bed
Left sideTurned 00:55
Bed 10PT-20935
In bed
ProneIn bed 7 h 10 m
Bed 11PT-20938
In bed
SupineIn bed 3 h 18 m
Bed 12PT-20931
Fall risk
Sitting upAt bed edge 02:09
Bed 13PT-20940
In bed
Right sideIn bed 6 h 02 m
Bed 14—
Empty
No patientReady since 16:45
Bed 15PT-20943
In bed
Left sideBack in bed 00:53
Bed 16PT-20946
In bed
SupineIn bed 5 h 47 m
Alerts tonight2 open
Bed 07 · Bed exit02:13
Not back after 1 minOpen
Bed 12 · Fall-risk indicator02:09
Sitting at bed edgeOpen
Bed 06 · Repositioning due02:04
No turn for 2 hAssigned
Bed 04 · Restlessness01:58
Frequent movement since 01:38Watching
Bed 07 · Bed exit01:22
Back in bed after 6 minResolved
Bed 15 · Bed exit00:47
Assisted, back 00:53Resolved
Bed 06 · Repositioned00:04
Left side to supineLogged
Sent to the ward station and on-call caregivers as they happen.
Early warning · PT-20877
Ward 2 · Bed 05 · compared with this patient's 7-night baseline
Add noteAcknowledgeSN
Combined pattern since 21:30: heart rate and breathing rising, HRV falling. Flagged for clinician review.flagged 02:10
Last 12 hours against baselineBaselineAlert limit
Heart rate
96bpm
+24 vs baseline
Alert 90 bpm14:0017:0020:0023:0002:00
Respiratory rate
23rpm
+8 vs baseline
Alert 22 rpm14:0017:0020:0023:0002:00
HRV (RMSSD)
21ms
−21 vs baseline
Alert below 25 ms14:0017:0020:0023:0002:00
Indicators against baseline
Heart rate
Baseline 68–76
96 bpm
Respiratory rate
Baseline 13–17
23 rpm
HRV (RMSSD)
Baseline 38–46
21 ms
Breathing irregularity
Baseline 0–2
6 per h
Restlessness
Baseline low
Moderate
Other patients on watch
PT-20931Ward 3 · Bed 12
Respiratory rate rising 2 h
Watch
PT-20902Ward 1 · Bed 03
HRV below baseline 3 h
Watch
PT-20944Ward 2 · Bed 09
Heart rate high 40 min
Review
Decision support for clinicians. Assessment and treatment stay with the care team.
Central station · all wards
Live vitals, alerts and reports for every monitored bed · 02:14
Bed or patient IDPatient reportSN
Beds monitored
32
Wards 1–3
Occupied
29
3 beds empty
Open alerts
4
Bed exit, fall risk, 2 vitals
On watch
4
Early-warning flags
Charted to EHR
02:00
Next write 02:15
All beds · liveAll wardsWard 1Ward 2Ward 3
BedPatientHRRRHRVStatusHR 2 h
W1 · B03PT-20902711629Watch
W1 · B05PT-20905641348Stable
W1 · B08PT-20909771736Stable
W2 · B02PT-20871691540Stable
W2 · B05PT-20877962321Review
W2 · B09PT-209441041927Review
W2 · B11————Empty—
W3 · B04PT-20922821833Restless
W3 · B07PT-20929———Bed exit—
W3 · B12PT-20931681542Watch
W3 · B16PT-20946621451Stable
IntegrationsAll connected
Hospital information system
Admissions, transfers and bed assignmentsConnected · ADT · last 02:11
Electronic health record
Vitals every 15 min, alerts and reportsConnected · last write 02:00
Caregiver alerts
Ward stations and on-call caregiversConnected · last sent 02:13
Monitoring platform
Hospital-hosted · 32 sensors onlineHealthy · v3.2.1 · synced
Patient reports
Early-warning summary
PT-20877 · 02:10
In EHR
Bed-exit log
PT-20929 · 02:14
Draft
Night summaries
All beds · 06:00
Scheduled

Heart rate, respiratory rate and heart rate variability, measured continuously from beneath the mattress using ballistocardiography (BCG), piezoelectric, fiber-optic, pressure-array or radar sensing.

Also in Contactless Patient Monitoring

  • Configurable Sensing

    Depending on the sensor configuration, the system adds mattress-interface temperature, weight estimation with load cells, cough detection, cardiorespiratory correlation, pressure distribution and prolonged-position monitoring.

Pricing

Quoted Per Deployment

Contactless Patient Monitoring is priced to the scope of each deployment: sites, devices, integrations and the support you need.

Quote for Contactless Patient Monitoring

Tell us how many sites and devices you operate and which systems it must connect to, and we will return a scoped quote.

Request a Quote

Common Questions